In an era where uninterrupted power is the lifeline of hospitals, data centers, and urban infrastructure, the sudden loss of electricity can trigger chaos. Imagine a hospital ICU during a critical procedure or a bustling airport amid peak travel—the stakes are immense. Addressing this need, YUYE introduces its cutting-edge YECT1-2000G Automatic Transfer Switch, a robust 2000 amp automatic transfer switch engineered to deliver seamless power transition when it matters most.
1.Uncompromising Reliability in Critical Moments
The YECT1-2000G excels as a vigilant guardian for power systems. When primary supply failures occur—due to phase loss, voltage fluctuations, or outages—this 2000a ATS swiftly reroutes loads to backup sources like generators or grid alternatives. Its “0-position” feature allows users to isolate loads from both supplies, a critical advantage during maintenance or emergencies. Designed as a PC-class device, it complies with GB/T14048.11 and IEC60947-6-1 standards, aligning with fire safety and emergency lighting codes for high-rise buildings. Rigorous aging tests and factory verification further ensure that every unit operates with precision.
2.Engineered for Diverse Applications
From telecommunications hubs to industrial assembly lines, the YECT1-2000G Automatic Transfer Switch adapts to complex environments. Its broad voltage range (AC380V–415V) and multi-current options (800A–2000A) cater to varied grid demands. With 3P/4P configurations and an impressive 120kA short-circuit withstand capacity, it safeguards Level 1 and 2 loads in sectors like healthcare, transportation, and broadcasting. The inclusion of a 16A control power current and 12kV impulse protection underscores its resilience.
3.Built to Endure Harsh Conditions
Unlike conventional switches, the YECT1-2000G thrives in challenging settings. It operates flawlessly in temperatures from -5°C to 40°C and handles humidity up to 90% at lower temperatures. Even in coastal areas with salty air or high-altitude installations up to 2000 meters, its ≥60mm arcing distance and Pollution Level 3 tolerance prevent performance degradation. The 2000 amp automatic transfer switch maintains stable operation even when facing occasional condensation or extreme temperature shifts, making it a versatile solution for global applications.
4.Simplified Maintenance for Long-Term Trust
YUYE prioritizes user-friendly upkeep. Experts recommend the first inspection within a year of installation, followed by annual check-ups. By disconnecting all external power during maintenance, professionals can ensure the 2000a ATS retains its reliability over its 3000-electrical/7000-mechanical cycle lifespan. Its modular design also streamlines component inspections, reducing downtime and ensuring that the system remains in optimal condition for years to come.
5.Conclusion: Power Continuity, Redefined
The YECT1-2000G Automatic Transfer Switch is more than a component—it’s a commitment to safety and operational continuity. By blending intelligent design with rugged durability, YUYE empowers industries to navigate power uncertainties confidently. For infrastructures where every second counts, this 2000a ATS stands as a dependable sentinel, bridging gaps in power supply with grace and precision. Its ability to combine robust performance with ease of maintenance makes it an ideal choice for modern facilities seeking to future-proof their power systems.
*Learn how the YECT1-2000G can transform your power resilience strategy—reach out to the YUYE team today.*
PC ATS YECT1-2000G
PC ATS YES2-63~250GN1
Solenoid-type ATS YES1-32~125N
Solenoid-type ATS YES1-250~630N/NT
Solenoid-type ATS YES1-32~125NA
Solenoid-type ATS YES1-63~630SN
Solenoid-type ATS YES1-1250~4000SN
Solenoid-type ATS YES1-250~630NA/NAT
Solenoid-type ATS YES1-63NJT
PC ATS YES1-100~1600GN1/GN/GNF
PC ATS YES1-2000~3200GN/GNF
PC ATS YES1-100~3200GA1/GA
Solenoid-type ATS YES1-63~630SA
Solenoid-type ATS YES1-63~630L/LA
Solenoid-type ATS YES1-63~630LA3
Solenoid-type ATS YES1-63MA
PC ATS YES1-630~1600M
PC ATS YES1-3200Q
Solenoid-type ATS YES1-4000~6300Q
CB ATS YEQ1-63J
CB ATS YEQ2Y-63
CB ATS YEQ3-63W1
CB ATS YEQ3-125~630W1
ATS controller Y-700
ATS Controller Y-700N
ATS Controller Y-701B
ATS Controller Y-703N
ATS Controller Y-800
ATS Controller W2/W3 Series
ATS switch Cabinet floor-to-ceiling
ATS switch cabinet
JXF-225A power Cbinet
JXF-800A power Cbinet
YEM3-125~800 Plastic Shell Type MCCB
YEM3L-125~630 Leakage Type MCCB
YEM3Z-125~800 Adjustable Type MCCB
YEM1-63~1250 Plastic Shell Type MCCB
YEM1E-100~800 Electronic Type MCCB
YEM1L-100~630 Leakage Type MCCB
Miniature circuit breaker YEMA2-6~100
Miniature circuit breaker YEB1-3~63
Miniature circuit breaker YEB1LE-3~63
Miniature circuit breaker YEPN-3~32
Miniature circuit breaker YEPNLE-3~32
Miniature circuit breaker YENC-63~125
Air Circuit Breaker YEW1-2000~6300
Air Circuit Breaker YEW3-1600
DC Isolation Switch YEGL3D-630
Load isolation switch YGL-63~3150
Load Isolation Switch YGL2-63~3150
Manual Changeover Switch YGL-100~630Z1A
Manual Changeover Switch YGLZ1-100~3150
YECPS2-45~125 LCD
YECPS-45~125 Digital
CNC Milling/Turning-OEM
DC relay MDC-300M