rated working current:16A-2000A
pole:3p,4p
Rated insulation voltage:690v/800v/1000v
Rated impulse withstand voltage:8kv/12kv
Rated working voltage:AC400V/50Hz
Use catagory:AC-33iB/AC-33B
1.Overview
This series of double power automatic transfer switch is suitable for automatic transfer between two power sources in emergency power supply system with rated working voltage of 400V and below,rated frequency of 50Hz and rated current of 16A to 3200A,to ensure continuous,safe and reliable operation of important loads(such as fire fightingload).It is widely used in hospitals,shopping malls,banks,chemical industry,high-risebuildings,military facilities,fire protection and other important places where power cutsare not allowed.
This product conforms to GB/T 14048.11-2016 Low-voltage switchgear and controlgear-part 6-1:multi-functional electrical switch appliances-switching device,conforms to "GB50045-1995 high-rise civil building fire code",2005 revision,"GB 5006-2014 Code for FireProtection in Building Design","GB 51309-2018 Standard for Fire Emergency Lighting andEvacuation Indication System","GB 17945-2010 Fire Emergency Lighting and EvacuationIndication System","GB51348-2019 Electrical Design Standards for Civil Buildings,etc.
2.Performance and characteristics
□ With overvoltage,undervoltage and open phase switching function.
□ The main loop adopts double breakpoint horizontal pull structure,connected and broken reliably;
□ In line with the requirements of the isolation switch standard,with clear on-off position indication and padlock,reliable isolation function;
□ There is a disconnect position(disconnect the common and standby power supply at the same time),to meet the requirements of fire linkage;
□ Four operating functions:emergency manual operation,electric remote control operation,automatic control state emergency disconnect operation Automatic control operation.
3.Normal working conditions
□The operating ambient temperature ranges from -5℃~+40℃,and the average temperature within 24 hours does not exceed+35℃.The ambient temperature ranges from-25℃~+55°℃,and can reach +70℃ in a short time(within 24 hours).
□The elevation of the installation site shall not exceed 2000m.
□The relative humidity of the air at the installation site should not exceed 50%when the ambient airtemperature is +40℃.The relative humidity can be higher at a lower temperature.For example,when the average minimum temperature of the wettest month is+20℃,the average maximum relative humidity of that month can reach 90%.Appropriate measures should be taken to prevent condensation caused by temperature change.
□Pollution Class 3(there is conductive pollution,orthe dry non-conductive pollution becomes conductive due to condensation
□ATSE can be installed vertically or horizontally in the cabinet.Special orders are required for special requirements.
□Product shell protection grade is IP20
□Overvoltage class
-Main circuit Class I
-Control and auxiliary circuits ClassII.
□Conversion controller and auxiliary circuit installation class:II.
| Frame size | 100 | 160 | 250 | 630 | 1600 | 3200 | |
| Rated operating current le(A) | 16,20,25,32,40 50,63,80,100 |
125,160 | 200,225,250 | 315,350,400 500,630 |
800,1000 1250,1600 |
2000,2500 3200 |
|
| Rated insulation voltage | 690V | 800V | 1000V | ||||
| Rated impulse withstand voltage | 8KV | 12KV | |||||
| Rated working voltage | AC400V/50Hz | ||||||
| Use category | AC-33B | AC-33iB | |||||
| Rated short circuit making capacity | 8KA | 17KA | 26KA | 67.5KA | 105KA | ||
| Rated short time withstand current | 5kA/30ms | 10kA/60ms | 12.6kA/60ms | 32kA/60ms | 50kA/60ms | ||
| Switching time | 2.5s | 1.2s/2.5s | 1.25 | 1.8s | 2.4s | ||