Insulation resistance:1000VDC,1000MΩ

Contact type: H

Maximum switching power :360kW

Vibrate:1.5mm double amplitude 10Hz~500Hz 49m/s²

humidity:5%~85%RH

temperature:-40C~85℃

Standard:IEC 60664-1

  • Description
  • Tags
  • 1.Characteristic

    1. Ceramic brazed seal eliminates the risk of arc leakage, ensuring no fire or explosion.
    2. Hydrogen-based gas filling effectively prevents contact oxidation and burn-out; contact resistance is low and stable, and the contact assembly meets IP67 protection standards.
    3. Capable of carrying 400A current at 85°C for extended periods.
    4. Insulation resistance reaches 1000 MΩ (1000 VDC), and the withstand voltage between contacts and coil is 3 kV, complying with IEC 60664-1 requirements.

     

    2.Performance parameter

    Insulation Resistance Disconnecting the main contacts Disconnect contacts
    from the coil
    1000VDC,
    1000MΩ
    1000VDC,
    1000MΩ
    Media voltage resistance Disconnecting the main contacts Disconnect contacts
    from the coil
    3000VAC 3000VAC
    1min 1min
    Leakage current 0.5 mA Leakage current 0.5 mA
    time parameter response time release time Absorption and rebound time
    ≤50ms ≤10ms ≤5ms
    Anti-vibration Stability Double amplitude: 1.5 mm; frequency range: 10 Hz to 500Hz; acceleration: 49 m/s²; duration per direction: 1 hour each; the time required to open or close a closed circuit shall not exceed 10 μs.
    Impact-resistant Stability 98 m/s² (pulse duration: 11 ms), performed 6 times (6 times in each of three mutually perpendicular axial directions, totaling 36 times); the time for opening a closed circuit or closing an open circuit shall not exceed 10 μs.
    Intensity 490 m/s² (pulse duration: 6 ms), 300 cycles(Each direction of the three mutually perpendicular axes, 50 times)
    standard test conditions Temperature 23℃±5℃
    Humidity 25%~75%RH
    Direction Standing
    Atmospheric Pressure 96×(1±10%)kPa
    service condition Temperature -40℃~85℃
    Humidity 5%~95%RH
    Installation Direction wantonly
    Storage Conditions Temperature -40℃~85℃
    Humidity 5%~95%RH
    Storage Period 12 months (original packaging)
    Environment The product storage area must be free from corrosive gases.
    During storage, avoid direct sunlight exposure to the product.

     