Insulation resistance:1500VDC,1000MΩ

Contact type: H

Maximum switching power :600 kW

Vibrate:1.5mm double amplitude 10Hz~500Hz49m/s²

humidity:5%~85%RH

temperature:-40C~85℃

Standard:IEC 60664-1

  • Description
  • Tags
  • 1.Characteristic

    1. Ceramic brazed sealing eliminates the risk of arc leakage, ensuring no fire or explosion occurs.

    2. The potting process uses a gas primarily composed of hydrogen, effectively preventing contact oxidation and burnout, resulting in low and stable contact resistance; the contact area meets the IP67 protection rating.
    Long-term current carrying capacity: 3,400 A at 85°C

    4. The insulation resistance reaches 1000 MΩ (1500 V DC), with a withstand voltage of 4 kV between contacts and the coil, complying with IEC 60664-1 requirements.

    5. The load has no polarity requirement, but coil drive requires specific polarity.

    6. Energy storage applications with safety compliance requirements for voltages ≤1500 VDC

     

    2.Performance parameter

    Insulation Resistance Disconnecting the main contacts Disconnect contacts
    from the coil
    Between the main contacts
    and the auxiliary contacts
    1500VDC,
    1000MΩ
    1500VDC,
    1000MΩ
    1500VDC,
    1000MΩ
    Media voltage resistance Disconnecting the main contacts Disconnect contacts
    from the coil
    Between the main contacts
    and the auxiliary contacts
    4000VAC 4000VAC 4000VAC
    1min 1min 1min
    Leakage current 0.5 mA Leakage current 0.5 mA Leakage current 0.5 mA
    time parameter response time release time Absorption and rebound time
    ≤50ms ≤20ms ≤5ms
    Anti-vibration Stability Double amplitude: 1.5 mm; frequency range: 10 Hz to 500 Hz; acceleration: 49 m/s²; duration per direction: 1 hour each; the time required to open or close a closed circuit shall not exceed 10 μs.
    Impact-resistant Stability 98 m/s² (pulse duration: 11 ms), performed 6 times (6 times in each of three mutually perpendicular axial directions, totaling 36 times); the time for opening a closed circuit or closing an open circuit shall not exceed 10 μs.
    Intensity 490 m/s² (pulse duration: 6 ms), 300 cycles(Each direction of the three mutually perpendicular axes, 50 times)
    standard test conditions Temperature 23℃±5℃
    Humidity 25%~75%RH
    Direction Standing
    Atmospheric Pressure 96×(1±10%)kPa
    service condition Temperature -40℃~85℃
    Humidity 5%~95%RH
    Installation Direction wantonly
    Storage Conditions Temperature -40℃~85℃
    Humidity 5%~95%RH
    Storage Period 12 months (original packaging)
    Environment The product storage area must be free from corrosive gases.
    During storage, avoid direct sunlight exposure to the product.

     

     3.Outline drawing

     

Click For Inquiry