  • “Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for High Quality China Hot Sale Moulded Case Circuit Breaker with Ce (EM6 Series), We look forward to providing you with our goods while in the in close proximity to long term, and you will discover our quotation is extremely realistic as well as high-quality of our solutions is incredibly outstanding!
    “Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for China Circuit Breaker, Mccb, To let customers be more confident in us and get the most comfortable service, we run our company with honesty, sincerity and best quality . We firmly believe that it is our pleasure to help customers to run their business more successfully, and that our skilled advice and service can lead to more suitable choice for the customers.

    Product detail

    Name Details
    Enterprise code Shanghai yuhuang electric co.,ltd
    Product category Moulded case circuit
    Design code 1
    Product code Moulded case earth leakage circuit breaker
    Current rank 100,225,400,630
    Breaking capacity L,M,H
    Pole 3P,4P
    Part No. 300 no part(please see the release part No.table)
    Rated current 16A~630A
    Use no. None=power distribution type breaker 2=protect handle operation
    Operation type None=manual direct operation,P=Electric operation,Z=Rotating handle operation
    N pole shape Four poles products’ N polar form:A type:N polar do not install over-current release,and N polar electric all the time,at the same time,N polar does not open and close together with other three.B type:N polar do not install over-current release,and N polar opens and closes together with other three poles.
    Writing None=front board connection,R=behind board connection,PR=Plug-in connection
    Release from V type,U type,W type,VA type
    Alarm module None=no alarm module,Ⅰ=alarm and trip,Ⅱ=alarm and don’t trip

    Product summary

    YEM1L series moulded case earth leakage circuit breaker(hereinafter referred to leakage circuit breaker) is applied in the circuit of AC 50/60HZ,its rated insulation voltage to 800V,rated working voltage to 400 V,rated current reaches to 630A.It is used to transfer infrequently and protect motor. Circuit breaker has over-load,short circuit and under-voltage protection function so that protects the circuit and power supply device from being damaged. At the same time,it can provide indirect contact protection for people, and it can also provide protection for fire rise which may be caused long-term ground faults that cannot be detected by over-current protection. When other protective devices fail, the leakage current circuit breaker YEM1L with a rated residual current of 30mA can directly act as an additional protection.
    1.This circuit breaker can be equipped with leakage alarm and non tripping module to avoid heavy losses caused by power failure.
    2.This circuit breaker has the features of small volume,high breaking ability,short arc and anti-vibration.
    3.Circuit breaker can be installed in a vertical way.
    4.The circuit breaker can not be poured into the line,that is only the 1、3、5 is allowed to connect the power line,and the 2、4、6 is connected to the load line.
    5.Circuit breaker has isolation function.

    Operating conditions

    1.Environment temperature:-5℃~+40℃.
    2.Altitude:≤2000m.
    3.The relative humidity of the air at the installation site does not exceed 50% at a maximum,for example:relative humidity of 90% at 20℃,special measures should be taken for condensation that occasionally occurs due to temperature changes.
    4.Pollution degree 3.
    5.The circuit breaker passes the GB/T2423.10 test requirement to withstand frequency of 20HZ~13.2HZ、displacement of ±1mm and frequency of 13.2HZ~100HZ、and an acceleration of ±0.7g.
    6.The main circuit installation category of the circuit breaker is Ⅲ,and the remaining auxiliary circuit and control circuit installation category is Ⅱ.
    7.The circuit breaker is suitable for electromagnetic environment A.”Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for High Quality China Hot Sale Moulded Case Circuit Breaker with Ce (EM6 Series), We look forward to providing you with our goods while in the in close proximity to long term, and you will discover our quotation is extremely realistic as well as high-quality of our solutions is incredibly outstanding!
    High Quality China Circuit Breaker, MCCB, To let customers be more confident in us and get the most comfortable service, we run our company with honesty, sincerity and best quality . We firmly believe that it is our pleasure to help customers to run their business more successfully, and that our skilled advice and service can lead to more suitable choice for the customers.